![]() The specification limit is 370 mg/stroke, so if you want to remain within OEM shop manual specifications for emission control reasons, you might have to enter a number slightly smaller than 33768. If all is well, enter 33768 as the "new" adaptation value and slect "test." Note that the displayed air intake volume changes, usually to about 370 mg/stroke. (If it does not show this, you are either on the wrong screen, or you have an older ECU that differs slightly - see next paragraph.) Note that the display will show a default adaptation value of 32768 and shows approximately 250 +/-20 mg/stroke of air intake volume. Give the accelerator pedal a quick "pat" to ensure that the EGR remains turned on for the next minute while you perform the following steps. ![]() ![]() Next, select "adaptation" then go to adaptation block 3. With a warm engine (full operating temp) and running at idle in neutral with all accessories turned off, connect VAG COM (VCDS) and start the software, select engine control module. ![]()